OWNER'S MANUAL

CP400 & CP700 COMMERCIAL
POWER AMPLIFIER

4

FRONT PANEL DESCRIPTION

Figure 1

1. Power Switch
This rocker switch supplies power to the amplifier. A red LED located above the power
switch will illuminate when the amplifier is switched on.

2. Protect LED Indicators
The amplifier features several types of protection circuitry to prevent damage during
power-up or fault conditions. If any of these LEDs illuminate, one of the various protection features is
safeguarding the amplifier. The output relays will disconnect the speaker loads when the protection
circuitry detects a fault condition.

Loudspeaker Protection

- When power is first applied, the speaker protection relay is

open, preventing transients from reaching the loudspeakers. After the internal power supplies

have stabilized, the relay will close, connecting the amplifier output to the load. The yellow

Protect LEDs will illuminate during this power-up process.

Thermal Protection - The amplifier protection circuitry monitors itself for excessive internal

operating temperatures. In the event this circuitry detects abnormal thermal conditions

(blocked cooling fan or high ambient temperatures), the speaker relay will disconnect the

speaker load from the amplifier. Once the internal operating temperature drops back to a safe

level, the relay will close, reconnecting the speaker load to the amplifier.

Short Circuit Protection - The yellow Protect LEDs will illuminate should the amplifier detect

a short circuit on the attached speaker load or if the load impedance is too low. When this

condition is detected, the internal speaker relays will open up, disconnecting the load from

the amplifier. The protection circuitry will stay activated until the fault is cleared.


Note: Once the specific fault has been corrected, the power may have to be cycled to reset the

protection circuitry.

3. Signal “Status” LED Indicator
The green “Status” LEDs will illuminate once the input signal has reached -26 dBV or higher.

+

+

-

-

GND

CH-2

CH-1

AMPLIFIER INPUTS

THRU

IN

THRU

IN

CAUTION

AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz

TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

POWER

CP700
Commercial
Power
Amplifier

Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V

PROTECT

LIMIT

SIGNAL

CH-1

PROTECT

POWER

LIMIT

SIGNAL

CH-2

CP700

Commercial Power Amplifier

LEVEL

-00

5

6

40

3

2

26

22

18 16 14 1

2 1

0 8

6

4

2

0

LEVEL

-00

5

6

40

3

2

26

22

18 16 14 1

2 1

0 8

6

4

2

0

1601 Jack McKay Blvd., Ennis, TX 75119

(800) 876-3333 AtlasSound.com

STEREO

PARALLEL

BRIDGE

GND

CH-1

CH-1

- 100V +

-

+

70V

-

+

25V

8, 4, and 2 Ohms

AUDIO TRANSFORMER

D I R . O U T P U T

I S O L . O U T P U T

-

+

70

100

0

BRIDGE

MONO

+

CH-2

CH-2

- 100V +

-

+

70V

-

+

25V

8, 4, and 2 Ohms

AUDIO TRANSFORMER

D I R . O U T P U T

I S O L . O U T P U T

-

+

70

100

0

BRIDGE

MONO

-

AVIS RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

MADE IN CHINA

2

3

4

1

Advertising