© Adam Equipment Company 2009

15

• The displays will then show the calibration weight suggested as a

whole number. For example:


“LoAd”

“04”

“KiLoS”

Either put this weight on the platform after the stable symbol is on
or enter the desired value in whole integer and then press

[Tare].

• Place the weight on the platform and press [Tare] again.

• At all times the scale should be stable before pressing the [Tare]

key to accept a weight. The stability indicator will turn on to show
the value is stable.

• When calibration is done the display will show “SPAn” “PASS”.

• Remove the weight. The scale will return to normal weighing.

• If an error message “SPAn” “FAIL” is displayed, then repeat the

process.

Suggested Calibration weights for CBC Series:

CBC 4 /
CBC 8a

CBC 8 /

CBC 16a

CBC 16 /
CBC 35a

CBC 32 /
CBC 70a

CBC 48 /

CBC 100a

2 kg / 5 Ib

4 kg / 10 lb

10 kg / 30 lb

20 kg / 50 lb

30 kg / 100 lb

• After calibration, the scale should be checked whether the

calibration and linearity is correct. If necessary, repeat calibration.


NOTE: CBCa scales will have the lb or kg indicator on, to show the unit of
the weight requested. If the scale was in pounds before starting the
calibration, the weights requested will be in pound values or if the scale was
weighing in kilograms then metric weights will be requested.

9.0 RS-232 INTERFACE


The CBC Series are supplied with a RS-232 bi-directional interface. The
scale when connected to a printer or computer through the RS-232 interface,
outputs the weight, unit weight and count.