Control Company 4142 BIG-DIGIT 4-ALERT THERMOMETER °C/°F User Manual

Control company

Advertising
background image

Traceable

®

is a registered trademark of Control Company ©2008 Control Company. 92-4142-00 Rev. 1 052008


OPERATING INSTRUCTIONS
Normal display shows inside and outside temp in 1/10 degree.

1. One point temp control

a. High Temp Alert “▲”
— Slide switch to temp “Alert” position, press “Alert Select” to select

High Temp Alert “▲” mode.

— Press “Hi Set” to set desired High Temp Alert.
— Press “Alert On/Off” to turn on the High Temp Alert. (“Alert” flag appears on

display.)

— Alarms and LCD flashes 5 sec every one min when the sensed temp is higher

than the set temp.

b. Low Temp Alert “▼”
— Slide switch to temp “Alert” position, press “Alert Select” to select Low Temp Alert

“▼” mode.

— Press “Lo set” to set desired Low Temp Alert.
— Press “Alert On/Off” to turn on the Low Temp Alert. (Alert flag

appears on display.)

— Alarms and LCD flashes 5 sec every one mm when the

sensed temp is lower than the set temp.

FITTING THE OUTSIDE SENSOR: LOCATE OUTSIDE SENSOR AWAY FROM
DIRECT SUNLIGHT AND HEAVY SATURATION.

2. Two point temp control
a. Inside Temp Alert “ ”
— Slide switch to temp “Alert” position, press “Alert Select” to select

Inside Temp Alert “ ” mode.

— Press “Hi set” to set the desired upper temp alert value.
— Press “Lo set” to set the desired lower temp alert value.
— Press “Alert on/off” to turn, on the Inside Temp Alert. (“Alert” flag appears on

display).

— Alarms and LED flashes 5 sec every one mm when the sensed temp is within the

set temp.

b. Outside Temp Alert “ ”
— Slide switch to temp “Alert” position, press “Alert select” to

select Outside Temp Alert “ ” mode.

— Press “Hi set” to set the desired upper temp alert value.

— Press “Lo set” to set the desired lower temp alert value.
— Press “Alert on/oft” to turn on the Outside Temp Alert. (“Alert” flag appears on

display)

— Alarms and LED flashes 5 sec every one mm when the sensed temp is outside the

set temp.

3. Slide switch to “Temp” position after setting temp alert.

4. Alert off
Press “Alert on/off” in temp “Alert” position, “Alert” flag disappears on display.

BATTERY REPLACEMENT:

1 Pc “AAA” or “UM4” battery

Insert the battery as direction indicated.

Use fingernail to lift up battery cover and insert battery as to indicated direction.

EASY MOUNTING OF BRACKET ON WALL BY:
— Double-sided tape or
— Screws


























WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:

CONTROL COMPANY

4455 Rex Road

Friendswood, Texas 77546 USA

Ph. 281-482-1714 Fax 281-482-9448

E-mail [email protected]

www.control3.com

Control Company is ISO 9001 Quality-

Certified by DNV and ISO 17025 accredited

as a Calibration Laboratory by A2LA.

TRACEABLE

®

BIG-DIGIT 4-ALERT THERMOMETER °C/°F INSTRUCTIONS