Nova-Tech LMI Series G - SD Metering Pump User Manual

Page 9

Advertising
background image

As the diaphragm starts forward on the discharge stroke
the pressure immediately rises inside the liquid end.
When the liquid end pressure rises above the discharge
line pressure, the discharge ball check is “pushed” up-
ward and the process fluid in the liquid end flows into
the discharge line. When the discharge stroke ends,
the diaphragm momentarily stops again. The pressure
in the liquid end equalizes with the discharge line pres-
sure and the discharge ball check reseats. The cycle
then starts again.

1.3 GENERAL SPECIFICATIONS

FLOW RATE:

Up to 115 GPH (430 L/H)

PRESSURE:

Up to 175 PSIG (12 BAR)

LIQUID END TYPE:

Mechanically Actuated Diaphragm

DRIVE TYPE:

Variable Eccentric

STEADY STATE ACCURACY:

±2% of pump full rated capacity between 10% and 100%
of rated capacity.

CAPACITY ADJUSTMENT:

Lockable stroke adjustment knob is adjustable from 0%
to 100% while pump is running.

LUBRICATION:

Drive is lubricated in an oil bath (Mobil SHC 629, 1 Quart).

TEMPERATURE:

Ambient and Liquid:

122

0

F (50

0

C) Maximum

14

0

F (-10

0

C) Minimum

3

PAINT:

Power Coating

SUCTION LIFT:

6.6 Ft (2 meters) of water column maximum

11.5 psia minimum internal pressure (3.2 psi maximum
vacuum)

WEIGHT:

38 lb (17.2 kg)

Advertising