INTRODUCTION

2.0 Introduction

LMI is the world’s most versatile manufacturer of economical and efficient metering
pumps. This manual addresses the installation, maintenance and troubleshooting proce-
dures for manually and externally controlled pumps. LMI has a worldwide network of
stocking representatives and authorized repair centers to give you prompt and efficient
service.

Please review this manual carefully. Pay particular attention to warnings and precautions.
Always follow good safety procedures, including the use of proper clothing, eye and face
protection.

2.1 Specifications

AD2XY

(where X is any number;

where Y is 1, or 8)

AD2XY

(where X is any number;

where Y is 2,3,4,5,6,7, or 9)

AD8XY, or AD9XY

(where X is any number;

where Y is any number)

Operating

Temperature

14 to 113°F

–10 to 45°C

14 to 113°F

–10 to 45°C

14 to 113°F

–10 to 45°C

Voltage

110 to 120 V

220 to 240 V

95 to 240 V

Frequency

50 to 60 Hz

50 to 60 Hz

50 to 60 Hz

Max. Current

2.0 A

1.0 A

1.4 A

Wattage

25 W

22 W

20 W

AD2

AD8

AD9

Battery

N/A

N/A

Panasonic BR1225 or

Renata CR1225 or

Energizer/Eveready

CR1220

Fuse

Bel Fuse 5HT1.25-R

Time-lag, 5mm x 20mm

Bel Fuse 5HT 2-R

Time-lag, 5mm x 20mm

Bel Fuse 5H 2-R

Time-lag, 5mm x 20mm

* The battery and fuse are internal, factory serviceable parts, and must be replaced by the factory or a qualified

distributor with parts of the same type and rating.