Wire requirements – Aprilaire Model 8570 User Manual

Page 6

Advertising
background image

- 2 -

Figure 1 and the table show the number of wires that must be available at the thermostat in stand-alone thermostat systems (i.e. not as
part of an Aprilaire

®

Model 6504 Intelligent Zone System). Figure 1 shows optional connections to both an outdoor temperature sensor and

an Aprilaire

®

Automatic Humidifier Control (AHC), but only one or the other can be used. All wire is standard 18-24 gauge thermostat cable.

When this thermostat is connected to a Model 6504 as
shown in Figure 2, only one four-wire cable need be run
from the thermostat to the Model 6504. Use standard
18-24 gauge thermostat cable.

OPTIONAL –

AUTOMATIC
HUMIDIFIER

CONTROL

(AHC)

HVAC

EQUIPMENT

MODEL 8570

THERMOSTAT

SEE

TABLE

2-WIRES

2-WIRES

2-WIRES

OPTIONAL –

OUTDOOR

TEMPERATURE

SENSOR

OPTIONAL –

INDOOR

TEMPERATURE

SENSOR

MODEL 8570

THERMOSTAT

MODEL 6504

4-WIRES

Application

# Wires

Diagram (Page)

Single-Stage Furnace/AC

5

1 (9)

Two-Stage Furnace/AC

7

2 (10)

Two-Stage Roof Top Unit

7

3 (11)

Boiler w/AC (2-transformer)

6

4 (12)

Radiant 1st Stage Heat,

6

5 (13)

Furnace 2nd Stage and AC

Single-Stage Heat Pump

6

6 (14)

Two-Stage Heat Pump

8

7 (15)

WIRE REQUIREMENTS

Figure 1 – Thermostat Wire

Figure 2 – Model 6504 Wire