PERKO 1240 User Manual

Surface mounted latch set, Spare parts, Mounting template

Advertising
background image

Cat. No. 1239 Series Latch Set with Regular Bevel and Box Strike
Cat. No. 1240 Series Latch Set with Reverse Bevel and Flush Strike

INSTALLATION INSTRUCTIONS

Read all instructions before proceeding.

TOOLS REQUIRED: 1/2 inch diameter drill, Phillips screwdriver, 1/8 hex key (supplied).

These surface mounted latch sets are designed to be mounted on the surfaces of doors
1/2 inch to1 inch thick.

1). Cut out template below. Fold on dotted line. Place template on door at desired height

on the side to have the latch set. The fold tab should overlap the door edge.

2). Mark center of 1/2 inch diameter hole.
3). Drill 1/2 inch diameter hole through door.
4). Assemble shaft to 'L' handle with set screw.
5). Insert 'L' handle shaft through latch set housing assembly.
6). Insert end of 'L' handle shaft through 1/2 inch diameter hole in door.
7). Align and fasten latch set housing assembly to door with (3) #8 oval head wood

screws (not supplied).

8). Insert cup in ring then place them over 'L' handle shaft on opposite side of door.
9). Insert retainer and 'D' handle into center of cup.

10). Fasten 'D' handle and retainer to 'L' handle shaft with #8-32 oval head screw.

11). Rotate cup to orient (2) mounting holes in a vertical position, then fasten cup to door

with (2) #8 flat head wood screws (not supplied).
CAUTION: For proper installation on plexiglass doors use cup mounting holes as tem-
plate to mark, drill and tap #8-32 holes. Substitute #8-32 flat head machine screws for
#8 flat head wood screws.

12). Mount strike plate or box strike to door frame with (2) #6 oval head or flat head wood

screws (not supplied).

NOTE: For continued ease of operation, periodically apply a lock cylinder lubricant.

Spare Parts

Item

Catalog Number

Box Strike Plate

0977000CHR

Flush Strike Plate

0912000CHR

Regular Bevel with Cam

0984000CHR

Reverse Bevel with Cam

0920000CHR

Surface Mounted Latch Set

1239INS1
4/04

PERKO, Inc.
16490 N.W. 13th Avenue
Miami, FL 33169-5707
www.perko.com

Mounting screws not supplied by Perko.

1/2 Inch Diameter

MOUNTING TEMPLATE

FOLD LINE

1-3/8 Inches

TA

Door Edge

Advertising
This manual is related to the following products: