Perma Pure MH-Series User Manual

Series humidifier user manual, Warning

Advertising
background image

PRINCIPLE OF OPERATION

Bulletin# 206

MH HUMIDIFIER SPECIFICATIONS

MH-070 humidifier’s performance is shown in
the chart below. The MH-110 which has a
slightly larger ID shows about a 3 degree higher
outlet dew point. MH-110 should be chosen
when a lower pressure drop is desired.

PERFORMANCE

MH-070 Performance Chart

A

MH™-Series Humidifiers are shell and tube
moisture exchangers that allow the transfer of
water vapor between a liquid water supply and a
flowing gas stream. Water is absorbed into the
walls of the Nafion

®

tube and transferred to the

dry gas stream. This transfer is driven by the
difference in partial pressures of water vapor on
the opposing sides.

Nafion

®

is a registered trademark of DuPont.

MH™ is a tradmark of Perma Pure LLC.

MH

- Series

Humidifier

User Manual

8 Executive Drive
Toms River, N.J. 08755
Phone: 800-337-3762

732-244-0010

Fax: 732-244-8140
e-mail: [email protected]
Web Site: www.permapure.com

PERMA PURE

Model Number

A

B

C

MH-(070 or 110)-12

14+/-1/4"

10"

1/4"

MH-(070 or 110)-24

26+/-1/4"

22"

1/4"

MH-(070 or 110)-48

50+/-1/4"

46"

1/4"

Sample Fittings 1/8" or 1/4", Purge Fitting 1/4" Compression.

INSTALLATION SPECIFICATIONS

Warning!

1. Use only de-ionized water.
2. Controlled temperature water.
3. Do not allow unit to dry out. If element dries

completely, soak in DI water for 1 hour.

Do not allow Nafion tube to dry out.
Nafion will shrink up to 125% and pull
out of the end fittings or break. Should
the element dry, soak it in DI water for
5 minutes before re-assembly.

MH-070 Humidifier Performance

0

10

20

30

40

50

60

70

12" 0.5

1

2

3

4

5

6

7

8

9

10

24"

1

2

4

6

8

10

12

14

16

18

20

48"

2

4

8

12

16

20

24

28

32

36

40

Flow Rate (l/min.)

Dew point (C)

Ambient

30 C

50 C

70 C

Advertising