22

M414545

Figure 3

Solvent gases and vapors from dry
cleaning machines create acids when
drawn through the heater of a drying
tumbler. These acids are corrosive to the
drying tumbler as well as to the laundry
load being dried. Be sure make-up air is
free of solvent gases and vapors.

If the dry cleaning machines are in the
same area as the tumbler, then the
tumbler make-up air must come from a
source free of solvent gases and vapors.

W058

WARNING

To reduce the risk of fire and
accumulation of combustible gases, DO
NOT exhaust tumbler air into a window
well, gas vent, chimney or enclosed,
unventilated area such as an attic wall,
ceiling, crawl space under a building, or
concealed space of a building.

W059

WARNING

T108IE3C

NOTE: Inside of duct shall be
smooth. Do not use sheet
metal screws to join sections.

NOTE: Do not install wire
mesh or screen in this
opening as lint will build up
and prevent proper discharge
of air from drying tumblers.

ROOF 30" (76.2 CM)

ROOF 30" (76.2 cm)

CEILING

WALL

36 INCHES

(91.4 cm)

RECOMMENDED

SERVICE AREA

24 INCHES

(61.0 cm)

MINIMUM

PARTITION OR

BULKHEAD

REMOVABLE STRIP OF PANEL IN FRAMING WALL

TO PERMIT REMOVAL OF DRYING TUMBLER

FROM FRAMING WALL

CONSULT YOUR LOCAL BUILDING
CODE FOR REGULATIONS WHICH
MAY ALSO APPLY

T075IE3A

FOR BEST PERFORMANCE
provide an individual exhaust
duct for each drying tumbler.
Do not install a hot water heater
in room containing drying
tumblers. It is better to
have the water heater in
a separate room with a
separate air inlet.

T108IE3A

TWO

DRYING

TUMBLERS

THREE

DRYING

TUMBLERS

ONE

DRYING

TUMBLER