The washer-extractor should be connected to an individual branch

circuit not shared with lighting or other equipment.

Electrical Specifications HC60, IHC012, IHC060

60 liters / 12 pounds

Boiler Fed/Steam Heat

Electric Heat

Code

Voltage

Cycle

Phase

Wire

Full
Load Amps

Recommended Circuit

Breaker (US-market)

AWG/mm2

kW Standard

Heating Elements

Full
Load Amps

Recommended

Circuit Breaker (US-

market)

AWG/mm2

US NON-US

US NON-US

N

440-480 50/60

3

3+PE

3

10

10

14/2.5

3x2 kW

12

15

16

14/2.5

P

380-415 50/60

3

3+N+PE

7

15

16

14/2.5

16

20

20

12/4.0

Q

200-240 50/60

3

3+PE

7

15

16

14/2.5

23

30

32

10/6.0

X

200-240 50/60

1/3

2/3+PE

7

15

16

14/2.5

N/A N/A

N/A

N/A

Alternative Electric Heat Options

N

440-480 50/60

3

3+PE

3x1.4 kW

N/A N/A

N/A

N/A

P

380-415 50/60

3

3+N+PE

13

15

16

14/2.5

Q

200-240 50/60

3

3+PE

18

20

20

12/4.0

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

Table 2