Ultra Start KEU-300 Series User Manual

Page 6

Advertising
background image

DIP Switch Settings
The DIP switches on the module are used to turn programmable features ON
and OFF. The following are the features that are controlled by the DIP
switches.

Switch #1 ON= Passive Arming
OFF= Active Arming

In Passive Arming Mode the alarm will automatically arm 30 seconds after
the last door is closed (Door pin connection required)

In Active Arming Mode the alarm will only activate when the lock button is
pressed on the remote transmitter.

Switch #2 ON= Chirps Disabled
OFF= Enabled
Turning this switch off will deactivate the Siren/ Horn Output.

Switch #3 ON= Horn Output
OFF= Siren Output
In Horn Output Mode the output on the Brown wire will pulsed.
In Siren Output Mode the output on the Brown wire will constant.

Switch #4 ON= 15 Second Disarm Mode
OFF= Sense Wire

When this switch is ON-
In this mode if the alarm is triggered the alarm cannot be disabled for 15
seconds. This prevents the system from being immediately disarmed with
the door lock switch.

When the switch is OFF-
The switch sense wire must be connected. The system will not disarm if the
system detects both the unlock and sense wire inputs.

Note: The system will only disarm if the Blue unlock wire is detected.

INSTALL MANUAL

REMOTE VEHICLE SECURITY

PAGE 6