16

4111-0001 — Sept. 2010

INSTALLATION

NOTE: For CleanPit models, proceed to step 17.

17. Standard models only:

a. Install shims under maintenance prop (D)

where prop attaches to leveler frame. Make
sure prop is solidly shimmed.

b. Raise maintenance prop (D) to the service

(upright) position and lock prop in this
position using an OSHA approved locking
device.

c. Proceed to step 18.

A— Platform Joists
B— Shim Locations (Under Platform

Cylinder Trunnions)

C— T- Frame (CleanPit Only)
D— Maintenance Prop (CleanPit

Model Shown)

E— Distance [8-1/2 in. (216 mm) Approx]

(Center of Leveler to Center of Prop
Mounting Plate)

CleanPit Model Shown

B

D

A

C

C

E