Adjustments, Valve adjustment procedure – Poweramp EH SERIES HYDRAULIC 4.2009 User Manual

Page 27

Advertising
background image

25

4111-0004 — November 2003
OCT 2007

ADJUSTMENTS

S1 Sequence Valve 1

Controls the the Platform Cylinder. When the leveler
has reached the top of its travel allow the leveler to float
down. Fluid should flow through the NV1 valve. If you
hear the motor spinning backwards, adjust S1
clockwise in small increments, testing each time, until
the motor is not spinning backwards. Once fluid is
flowing through NV1, and motor stops turning
backwards, turn S1 one full turn clockwise. This will
ensure it will have enough spring resistance to shift
after the spring settles.

S2 Sequence Valve 2

Controls the Lip Cylinder. This valve should be set to
allow a smooth, quiet shift. Turning S2 counter-
clockwise causes the lip to extend.

If the lip does not extend turn S! counter-clockwise in
small increments until lip begins to extend. Once the lip
is extended allow the powerpack to operate in pressure
relief , then allow the leveler to return below dock.

Raise the leveler and continue to adjust the S2 valve to
allow a smooth, quiet shift. When adjusted properly, the
lip should stay extended until below dock. Lip
extension cycle should not take more than a few
seconds.

NV1 Need Valve 1

Controls the Downspeed of the ramp cylinder.
Increase Downspeed by turning NV1 counter-
clockwise,
Decrease Downspeed by turning NV! clockwise.

RV2 Relief Valve 2

Allows the lip to collapse below dock, protects the lip if
it is backed in to. Set the RV2 valve by backing out
adjustment screw as far as it goes.

Return leveler to keepers and begin to raise it.
Halfway up, allow the leveler to return for a second,
then raise leveler. The lip should not extend. If lip
extends, turn S2 valve clockwise 1/4 turn and repeat
until lip does not extend.

PO CHK Pilot Operated Check Valve

Keeps Lip from collapsing until it is below dock. This
valve is not adjustable. I lip malfunctions, cleaning or
replacement may be required.

RV1 Main Relief Valve

Sets system pressure

2W 2 Way Normally Open Spool Valve - Optional

If present, can extend lip with Lip Out option or it can
be used as an emergency stop if power is not running.

A—S2 Valve
B— RV1 Valve

C—S1 Valve
D— 2W NO Spool Valve/Coil

E— NV1 Valve
F— Breather Tube/Fitting

G—To Hoist Cylinder
H—To Lip Cylinder

*Note: Not pictured on the bottom of the valve body are the RV2 and PO Check Valves

Valve Adjustment Procedure

B

A

D

F

E

G

H

C

Advertising