Troubleshooting – Poweramp LMP SERIES MECHANICAL 4.2009 User Manual

Page 29

Advertising
background image

TROUBLESHOOTING

27

4111-0013 — Aug. 2007
Dec.2008

Symptom

Possible Cause

Solution

Platform does not rise.

Heavy object(s) on platform. Remove object(s) from platform.

NOTE: For safety reasons, the dock leveler is

designed to lift only the platform’s own
weight.

Disconnected or broken
release cable.

Connect or replace cable.

Dock leveler binds.

Check for visible obstructions that could cause
binding. Check weather seal if equipped.

If no obstructions found, call Poweramp Technical
Services. See inside back cover for phone number
and address.

Platform rises slowly or
does not rise to the full
raised position.

Heavy object(s) on platform. Remove object(s) from platform.

NOTE: For safety reasons, the dock leveler is

designed to lift only the platform’s own
weight.

Dock leveler binds.

Check for visible obstructions that could cause
binding. Check weather seal if equipped.

If no obstructions found, call Poweramp Technical
Services. See inside back cover for phone number
and address.

Insufficient main spring
tension.

Increase tension on main springs. (See Adjust Lift
Arm Spring and Lip Assist Spring Tension in the
Adjustments section.)

Damaged or worn
hold-down mechanism.

Clean and inspect hold-down mechanism.

Troubleshooting

Always stand clear of the dock leveler lip when
working in front of the dock leveler. Failure to do
this may result in serious personal injury or death.

The platform maintenance prop MUST be in the
service position when working under the dock
leveler. For maximum protection, use an OSHA
approved locking device to lock the maintenance
prop in the service position. Only the person
servicing the equipment should have the key to
unlock the maintenance prop.

Failure to follow these instructions may result in
serious personal injury or death.

Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete. Failure to do this may
result in serious personal injury or death.

Advertising