Qlogic br-1860, Data sheet – QLogic BR-1860 Fabric User Manual
Page 5

BR0058006-00 Rev. A 03/14 5
QLogic BR-1860
Data Sheet
Fibre Channel Specifications
Data Rate
•
14.025Gbps (1600MBps); 8.5Gbps
(800MBps); 4.25Gbps (400MBps); 2.125Gbps
(200MBps) auto-sensing (per port); full duplex
Performance
• Over 500,000 IOPS per port
(1,000,000 IOPS per dual-port adapter)
Topology
• Point-to-point (N_Port), switched fabric (N_Port),
FC-AL, FC-AL2
Key Features
• Dynamic fabric provisioning (DFP). Fibre Channel
fabric assigned worldwide name (FA-PWWN)
• D_Port. Port type enabling rapid isolation of optics or
cable problems
• Credit recovery. Buffer credit loss detection and
automatic recovery at 16GFC
• Forward error correction (FEC): error recovery
mechanism when operating at 16Gbps link speed
• N_Port trunking. Aggregation of 2×16Gbps links
into a single logical 32Gbps link
Distance Support
• 15m at 16Gbps on 62.5/125μm (OM1) multimode
fiber (MMF)
• 35m at 16Gbps on 50/125μm OM2 MMF
• 100m at 16Gbps on 50/125μm OM3 MMF
• 125m at 16Gbps on 50/125μm OM4 MMF
• 10km at 16Gbps on 9/125μm single-mode fiber
(SMF)
Ethernet Specifications
Data Rate
• 10.3125Gbps
Distance Support
• 33m at 10Gbps on 62.5/125μm OM1 MMF
• 82m at 10Gbps on 50/125μm OM2 MMF
• 300m at 10Gbps on 50/125μm OM3 MMF
• 10km at 10Gbps on 9/125μm SMF
Frame Sizes
• All standard Ethernet frame sizes supported,
including 9,600 byte jumbo frames and mini-jumbo
frames
Boot Options
• Pre-boot execution environment (PXE and gPXE),
BIOS, UEFI
FCoE Specifications
Performance
• Over 500,000 IOPS per port
(1,000,000 IOPS per dual-port adapter)
Host Specifications
Server Platform
• Intel (IA32, IEM64T), AMD (x86, 64), and
Sun
®
(x86, SPARC
®
)
Bus Interface
• PCI Express Gen 2.0 compatible (x8), with MSI-X and
INTx
Software
Management
• QLogic Host Connectivity Manager (HCM)
• QLogic BCU CLI
Operating Systems
• For the latest applicable operating system information,
.
Physical Specifications
Form Factor
• PCI Express low-profile form factor;
16.77cm×6.89cm (6.60in.×2.71in.)
Environmental and Power Requirements
Airflow
• 45 linear feet per minute (LFM)
Operating Temperature
• 0ºC to 55ºC /32ºF to 131ºF (dry bulb)
Non-Operating Temperature
• −43ºC to 73ºC/−40ºF to 163ºF (dry bulb)
Operating Humidity
• 5% to 93% (relative, non-condensing)
Non-Operating Humidity
• 5% to 95% (relative, non-condensing)
Operating Voltage
• 12V
Agency Approvals
United States
• Bi-Nat UL/CSA 60950-1 2nd Ed; ANSI C63.4;
cCSAus; FCC Class B
Canada
• Bi-Nat UL/CSA 60950-1 2nd Ed; ICES-003 Class B;
cCSAus
Japan
• CISPR22 Class B and JEIDA (Harmonics); VCCI-B
European Union
• EN60950-1; EN55022 Class B and EN55024;
TÜV Bauart, CE Mark
Australia, New Zealand
• EN55022 and CISPR22 Class B or AS/NZS CISPR22;
C-Tick
Russia
• IEC60950-1; 51318.22-99 and .24-99; GOST Mark
Korea
• KN22 and KN24; KC Mark Class B
Taiwan
• CNS 13438(95) Class A; BSMI Mark
Ordering Information
BR-1860-1
xxx (single port)
• Ships in a single pack with low-profile and standard
brackets
BR-1860-2
xxx (dual port)
• Ships in a single pack with low-profile and standard
brackets