G. initial settings – Fulton VMP Webster Oil_Combo Burner User Manual

Page 28

Advertising
background image

Page 28

Initial Settings

JB Manual

G. INITIAL SETTINGS

The burner will be set at the factory for normal ini-

tial settings. These are only rough settings that

must be adjusted at startup to match the furnace,

fuel pressure and environment of the specific ap-

plication. These general settings are covered in

this chapter as a means of checking the burner

(linkage and settings can move in shipment) or

readjusting the burner if the settings are lost.

1. Oil nozzle position

The oil nozzle initial position is shown in Figure

G-2. The oil nozzle will be adjusted at start-up

and may be moved in or out from this initial set-

ting. In some cases, the oil nozzle may be inside

the diffuser

PRESSURE ATOMIZED NOZZLE

AIR ATOMIZED NOZZLE

Model Diffuser

I.D.

Qty.

Spray

Angle

Dimension

Inches

Diffuser

I.D.

Nozzle

Type

Spray

Angle

Dim.

A

Dim.

B

JB1

1 1/2”

2

30

3/8

NA

NA

NA

NA

NA

45

1/4

1

30

7/8

45

3/4

JB2

1 3/4”

2

30

3/4

2”

Single

Port

60o

1/4”

NA

45

5/8

60

1/2

JB3

2 1/2”

3

60

5/8

2 1/2

Multi

Port

80o

NA

3/8

2 7/8”

3

60

5/8

2 7/8

INNER FIRE CYLINDER

B

Figure G-1

Oil Nozzle Position,

Gas Pilot

Chart G-2

Flexible Strip

Cam

Cam Set Screws

Adjusting Screws

Aluminum Strip

End Screws
Spring

End Screw

Adjusting Nut

Cam Follower

Retention

Plate

Roller Washers

Roller

Cam Follower

Return

Springs

Jack

Shaft

Figure G-3

Fuel Cam Adjustment

High Fire

Position

Low Fire Position

Advertising