Welch Vacuum 2561B-50 WOB-L Pinston Pump User Manual

Page 10

Advertising
background image

Section 5: TROUBLESHOOTING

5.10 VACUUM

PROBLEMS

Welch dry vacuum pumps are 100% oil-free. The pump employs a non-lube piston and
cylinder. Leakage, contamination and unusual outgassing are the general causes of problems
with poor vacuum. To operate at maximum effi ciency a system must be thoroughly clean. If
the system is completely clean and free from leaks, and unwarranted vacuum problems still
exist, the pump should be checked. A simple criterion for the condition of the pump is the
determination of its maximum vacuum capability. This can be accomplished by blocking of the
intake and reading the vacuum level on the gauge (See Section 2.8).

5.20 TROUBLESHOOTING

TABLE

Poor

Pumping

Speed

Poor

Vacuum

Loud

Unit

Possible Cause

Corrective Action

X

X

X

Damaged valves

Replace fl apper valves

X

X

X

Debris in valves

Remove debris and check for valve damage

X

X

X

Damaged gasket

Replace gasket

X

X

X

Loose head screw

Tighten head screw

X

X

X

Loose fi tting

Tighten fi tting

10