Welch Vacuum 2581B-50 WOB-L Pinston Pump User Manual

Page 10

Advertising
background image

10

Section 5: TROUBLESHOOTING

5.10 Vacuum Problems

Leakage, contamination and unusual outgassing are the general causes of problems with poor vacuum.

To operate at maximum efficiency a system must be thoroughly clean. If the system is completely clean

and free from leaks, and unwarranted vacuum problems still exist, the pump should be checked. A

simple criterion for the condition of the pump is the determination of its maximum vacuum capability.

This can be accomplished by blocking of the intake and reading the vacuum level on the gauge

(See Section 2.8).

5.11 Troubleshooting Guide

Poor

Pumping

Speed

Poor

Vacuum

Loud

Unit

Possible Cause

Corrective Action

X

X

X

Damaged valves Replace flapper valves

X

X

X

Debris in valves

Remove debris and check for valve damage

X

X

X

Damaged gasket Replace gasket

X

X

X

Loose head screw Tighten head screw

X

X

X

Loose fitting

Tighten fitting

Advertising