Programming Information

19

AXB-TC and AXB-TCR Television Controllers (& Receivers)

Send_Commands (Cont.)

'PTOF',<Time>

Sets the IR power-off pulse time after a power-on pulse in increments of
.10 seconds. Time is stored in permanent memory.
Variable:

<Time> = 0-255; System default = 15 (1.5 seconds).

Example:

SEND_COMMAND 55,"'PTOF',15"

Sets the power-off pulse time after a power-on pulse to 1.5 seconds for
device 55.

?PTOF

Sends the current IR power-off pulse time string "'PTOF', <Time>" to the
master. Set the <Time> value in .10 second increments.
Example:

SEND_COMMAND 55,'?PTOF'

Sends the current IR power-off pulse time from device 55 to the master.

'PTON',<Time>

Sets the IR power-on pulse time in increments of .10 seconds. Time is
stored in permanent memory.
Variables:

<Time> = 0-255; System default = 5 (.5 second).

Example:

SEND_COMMAND 233,"'PTON',20"

Sets the IR power-on pulse time (delay) to 2 seconds for device 233.

?PTON

Sends the current IR power-on pulse time string "'PTON',<Time>" to the
master. Set the <Time> value in .10 second increments.
Example:

SEND_COMMAND 233,'?PTON'

Sends the current IR power-on pulse time from device 233 to the mas-
ter.

'RO',<Offset>

Sets the offset value subtracted from the IR function before sending the
code to the master.
Variables:

<Offset> = 0-255

Example:

SEND_COMMAND 62,"'RO',5"

Subtracts 5 from the incoming IR code number and sends the appropri-
ate IR function from device 62 to the master.

'SP',<IR out>

Generates a single <IR out> function pulse. The 'CTON' (pulse on) and
'CTOF' (pulse off) commands set the pulse time.
Variable:

<IR out> = 1-127 (see theIR Functions (Standard Order) table on
page 16)

Example:

SEND_COMMAND 225,"'SP',25"

Decreases the volume level on the equipment connected to device 255.