FEC AFC1500 User Manual

Page 2

Advertising
background image

AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 6 - 2

Chapter 6: Troubleshooting

6.1 Abnormals

The Multi-2 Unit is capable of giving unit fault status to the AFC 1500 User Console in the form of a

code number. This number can be read and displayed by the User Console software. (See the User

Console Software Manual for more information on where to access this function)

Abnormal

Number

Description

1

An Axis unit was not in Ready status when the Multi-2 Unit

attempted to start - confirm all axis status

2

The connected spindles do not match with spindles called

from fastening sequence - confirm fastening sequence

3

Fastening sequence does not have spindle numbers

assigned - confirm fastening sequence

4

Fastening sequence selected does not exist - confirm

fastening sequence.

5

No End command in the fastening sequence

6

Fastening sequence abnormal

7

An Axis unit was not in Ready status when the Multi-2 Unit

attempted to send 1st step command - confirm all axis

status

8

An Axis unit was not in Ready status when the Multi-2 Unit

attempted to send 2nd step command - confirm all axis

status

9

Input / Output port number error - input port number over 4

or Output port number over 8 is set

Advertising