FEC AFC1200 User Manual

Page 2

Advertising
background image

)(& ,QF

8.1

Inspection Items

A scheduled inspection is recommended to keep the AFC1200 System in the best condition.
A preventive maintenance routine should be practiced monthly.

WARNING: Follow Lockout/Tagout and other safety precautions when

connecting or disconnecting cabling, wiring, and equipment.
Always verify the System is disabled prior to touching any
moveable components.

8.1.1 Nutrunner (Tool)

It is important to keep the nutrunners clean and properly adjusted to ensure correct fastening
and accurate System outputs. Inspect each tool, and ensure the following conditions exist:

{ All environmental conditions are within the specified ranges.

{ The duty cycle is within specifications, and the motor is producing normal heat levels.

{ The tool is producing normal levels of noise and vibration.

{ The tool is free from excessive contamination and foreign matter.

{ The tool is securely mounted, with mounting bolts properly tightened.

{ The preamplifier, mounting clips, and cable ties are correctly and securely fastened.

{ The homerun cables are securely connected to the tool.

8.1.2 Spindle Assembly

The torque and stress generated during each fastening is applied directly to the spindle
assembly. Inspect each assembly, and ensure the following specifications are met:

{ The spindle assembly is producing normal levels of noise and vibration.

{ The assembly is free from excessive contamination and foreign matter.

{ The spindle assembly is securely mounted, with mounting bolts properly tightened.

{ The square drive or socket is in good condition, and there is no excessive wear.

{ The spindle assembly rotates and compresses freely, with no binding.

8.1.3 Homerun cables

These cables connect the tool to the Axis Unit. Ensure the following conditions are met:

{ The cables are free from unnecessary force, tension, and pinching.

{ The cables are secured away from any movement.

{ The cables are in good condition, sufficiently insulated with no indication of broken wires.

{ The cables are free from excessive contamination and foreign matter.

{ The cables are securely connected to the Axis Unit and to the nutrunner.

{ The cables are free from heat distortion, and are not warm or hot to the touch.

{ The cables, cable connectors, and connector screws are securely and correctly fastened.

WARNING: Follow Lockout/Tagout and other safety precautions when

Chapter 8: Maintenance and Inspection

Page 8-2

Advertising