FEC AFC1150 User Manual

Page 8

Advertising
background image

)(& ,QF

6.4 Timed Speed Change Set-Up

w Slow Start Time switches are used to

select the length of time the equipment
will operate in slow speed prior to
accelerating to high speed when
operating in speed change mode.

w Verify power is off, or bypass mode has

been selected and In Bypass switch is
lit, prior to changing the setting of the
Slow Start Time switches.

w Do not change this set-up while the

tool is running because it may result in
operation errors or accidents.

w Refer to the following table for the time

values of each switch.

Fig. 6.4

4 seconds

1

3 seconds

2

Actual time may vary slightly.

2 seconds

3

Times listed in this table are approximate.

1 second

4

SLOW SPEED

SWITCH

TIME IN

SELECTED

NOTE: Select only one time switch. Times are not cumulative, and the maximum

approximate time available prior to acceleration is 4 seconds.

CHAPTER 6: PRE-SETS AND OPERATION

Page 6 - 8