FEC AFC1100 User Manual

Page 7

Advertising
background image

)(& ,QF

P Axis units must be located a minimum of 600 mm from high transient voltage sources

such as transformers, motor starters, AC inverters, and AC contactors. If this cannot
be avoided, then the units must be properly shielded.

{ Static Electricity

AFC1100 System construction incorporates many electronic Surface Mounted Devices
(SMD). It is advisable to strictly adhere to practices for safe electrostatic discharge in
order to prevent damage to the System.

{ Cleaning

Do not use any organic solvents, such as thinner, to clean an Axis unit or a tool. The
solvent could melt the surface paint, or penetrate inside and cause damage. A cloth
dampened with alcohol or warm water should be used to lightly wipe the components.

{ Handling and Shipping

It is critical that AFC1100 System components are properly handled and shipped in
order to maintain the System's integrity. Adhere to the following requirements for
shipping and handling:

P All AFC1100 components must be removed from the enclosure(s) prior to shipping.

P AFC1100 System components must be individually packaged in an approved

anti-static container or wrap to prevent damage from electrostatic discharge.

P Tool assemblies must be removed from the powerhead during shipment to prevent

damage to the transducer assembly.

P Enclosures must be protected with shrink wrap.

P Enclosures and System components should be shipped on an air ride trailer

whenever possible.

P Adhere to Chapter 2 Specifications for environmental requirements.

Chapter 1: Outline (Rev. 8/98)

Page 1-7

Advertising