FEC AFC1100 User Manual

Page 5

Advertising
background image

)(& ,QF

2.4

Axis Unit

{

200~230 VAC, 3-Phase, 50/60 Hz

AXIS UNIT INPUT POWER

100A

70A

70A

50A

50A

50A

AXIS UNIT IN-RUSH CURRENT

4A

2A

2A

1A

.625A

.625A

AXIS UNIT PEAK CURRENT

400W

200W

200W

100W

70W

60W

TOOL MOTOR RATING

MFA040

HA1NS

BXE020-

A912

MFA020

HA2NSA

MFA010

HA2NSA

BNE006-

A117

MFA006

HA2NSA

TOOL MOTOR MODEL
NUMBER

M4

W3

M3

M2

W1

M1

TOOL MOTOR TYPE

AXIS-110

AXIS-105

AXIS-103

AXIS UNIT TYPE

{ CPU:

V25 - NEC @ 16 bits

{ Data communications:

1 RS422 communications port configurable for User Console
communications or raw data output

Example:

Tool (nutrunner) model DFT-401M2-S has an M2 motor type, and must be used

with a Type 203 Axis Unit.

NOTE:

The M1 and W1 motors are functionally identical units, and can be interchanged
without any special considerations. The same is true of the M3 and W3 motors.

CAUTION:

If the equipment is powered on and off repeatedly, the circuit breakers might
trip due to the in-rush current.

Chapter 2: Specifications (Rev. 8/98)