FEC AFC1100 User Manual

Page 5

Advertising
background image

)(& ,QF

Maximum allowable Final step time

FINAL STEP (TIME)

Maximum allowable fastening cycle time

1ST STEP (TIME)

Engineered fastening specification for rotation angle

STD ANGLE

30 ~ 50% of resultant torque for Hard joints
50 ~ 90% of resultant torque for Soft joints

SPEED CHANGE (TORQUE)

Engineered fastening specification at which angle control
begins

SNUG (TORQUE)

30 ~ 50% of FINAL ANGLE or resultant torque for Hard joints
50 ~ 90% of FINAL ANGLE or resultant torque for Soft joints

1st TORQUE/ANGLE

RECOMMENDATION

FUNCTION

{ Two-Step Fastening

P The System fastening parameters must be configured according to the Engineered

fastening specification.

P Two-step fastening will be used primarily for joints that have a requirement to

synchronize with another spindle during the final stage of the rundown.
Examples: Connecting rod, main bearing cap, any multiple-spindle unit.

P The System will fasten to the 1st TORQUE/ANGLE during the specified 1ST STEP

time. Once either SPEED CHANGE TORQUE or 1st TORQUE/ANGLE is
reached, the System will switch to the specified TORQUE SPEED (Section 6.3).
When all fasteners have reached 1st TORQUE/ANGLE, the spindles will
synchronize and rotate simultaneously the specified number of degrees from
SNUG TORQUE to STD ANGLE within the specified FINAL STEP time.

STEP

TORQUE

FINAL

STEP

FINAL ANGLE

1ST

STEP

1ST

ANGLE

SNUG TORQUE

ANGLE
(TIME)

SPEED CHANGE

TORQUE

FIG. 6-1-2b Angle Control Functions for Two-Step Fastening

Chapter 6: Fastening Instructions (Rev. 1/98)

Page 6-5