X75 metallic flap valve pump design level 2, Capacity, Head – Blagdon Pump X75 Metallic Flap Valve User Manual

Page 3: Model hdf3-m /hdf4-m performance curve, Air-operated double diaphragm pump

Advertising
background image

x75mfvmdl2sm-rev0411

Page 1

INTAKE/DISCHARGE PIPE SIZE

HDF3-M: 3" 150# ANSI Flange

HDF4-M: 4" 150# ANSI Flange

CAPACITY

0 to 260 gallons per minute

(0 to 988 liters per minute)

AIR VALVE

No-lube, no-stall

design

SOLIDS-HANDLING

Up to nearly 3" (75mm)

HEADS UP TO

125 psi or 289 ft. of water

(8.8 Kg/cm

2

or 88 meters)

Pumps are designed to be powered only by compressed air.

U.S. Gallons per minute

10

0

0

20

30

40

50

60

70

80

90

100

20

40

60

80

100 120 140 160 180 200 220 240 260

20(34)

60 PSI

40 PSI

40(68)

60(101.9)

80(135.9)

100(169.9)

120(203.9)

140(237.9)

160(271.8)

180(305.8)

20 PSI Air Inlet Pressure

100 PSI

80 PSI

Liters per minute

CAPACITY

0

100

200

300

400

500

600

700

800

900

1000

AIR CONSUMPTION

SCFM (M

3

/hr)

PSI

BAR

HEAD

0

1

2

3

4

5

6

7

200(339.8)

MODEL HDF3-M /HDF4-M Performance Curve

Performance based on the following: elastomer fitted pump, flooded suction,

water at ambient conditions. The use of other materials and varying hydraulic

conditions may result in deviations in excess of 5%.

X75 Metallic Flap Valve Pump
Design Level 2

Air-Operated

Double Diaphragm Pump

ENGINEERING, PERFORMANCE

& CONSTRUCTION DATA

II 2GD T5

See page 17

for ATEX ratings

Advertising
This manual is related to the following products: