DUAL PORTING OPTIONS

Several dual porting options are

possible. The pump can be converted
to a dual port arrangement on both the
suction and the discharge ends. The
porting can be configured to a single
suction and a dual discharge. The porting
can be changed to a dual suction and a
single discharge.

The above changes are possible

because the porting flange of the elbows
(items 19) are designed to mate with
standard 125# ANSI style 4-bolt, 3" pipe
flanges.

Dual porting of both suction and
discharge ends of the pump

Converting the pump from the

standard single suction and discharge
porting configuration to dual porting at
each end is easy. Simply remove the
manifold seals, spacers, and manifolds
(items 36, 39, and 24 from pump
assembly drawing) from the pump.

The discharge and suction elbows

can be rotated at 90° increments (see
arrows and optional positioning in the
Dual Porting Drawing.

Single porting of the suction and dual
porting of the
pump discharge

To convert the pump from the

standard single suction and single
discharge porting configuration to a dual
discharge porting arrangement remove
the only the discharge manifolds,
spacers, and manifold seals. Position the
discharge elbows in the desired direction
at 90° increments. (See arrows and
optional positioning in the Dual Porting
Drawing.)

Dual porting of the suction and single
porting of the pump discharge

To convert the pump from the

standard single suction and single
discharge porting configuration to a dual
suction porting arrangement remove the
only the suction (bottom) manifolds,
spacers, and manifold seals.

Position the suction elbows in the

desired direction at 90° increments. (See
arrows and optional positioning in the
Dual Porting Drawing.)

Read these instructions

completely, before in-

stallation and start-up. It

is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.

IMPORTANT