Exhaust safety when pumping hazardous liquids, High temperature instructions – Blagdon Pump X50 FDA User Manual

Page 9

Advertising
background image

HG-CF-1121 Rev. D - 09.01.11

b50_x50_FDA_manual-rev0911

Page 9

HG-CF-1121 Rev. C - 11/01/10

PAGE 9

EXHAUST SAFETY WHEN PUMPING HAZARDOUS LIQUIDS

Suction Lift Installation

Flooded Suction Installation

Submerged Installation

Exhaust Safety :-

When a diaphragm fails during operation, pumped liquid can enter and contaminate the air side of the pump. If diaphragm failure is not

severe, i.e. a small split or hole, then the pump can continue to run, with air being forced into the product being pumped. If however the

failure is more serious, then the pump may stop, with fluid or fumes being expelled through the exhaust. Under these conditions it is

recommended that the exhaust is piped away to a safe area. In standard suction lift conditions this can simply be done by piping from the

exhaust connection to a safe area. Multiple installations can be piped to a common connection, then to a safe area. In flooded suction

conditions the exhaust must be taken to a point higher than the fluid level to prevent any siphoning away. In submerged conditions ensure

exhaust is piped away above fluid level.

In all conditions ensure exhaust outlet is not expelling across a non-conductive surface. The exhaust must not be placed less than 100mm

from any non-conductive surface, as this may generate a propagating brush discharge resulting in a possible ignition source.

In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping

a product which is hazardous or toxic, the air exhaust must be piped to an appropriate area for safe disposition.

WARNING!

REF. NO

15

17

18

24

33

34

39

49

MATERIAL

DESCRIPTION

BUMPSTOP

O-RING

DIAPHRAGM

SHAFT BUSH

O-RING

VALVE BLOCK

SEAL

PORT SEAL

O-RING

SUPPORT

DIAPHRAGM

VITON

1B177

G324

-

G323

50-282

1B176

G329

1B003

PHOSPHOR BRONZE

-

-

50-281

-

-

-

-

-

HIGH TEMPERATURE SPECIFICATION

In situations where the temperature of the fluid to be pumped is likely to exceed 100°C, a high temperature pump

code must be specified. This is signified using an ‘X’ in the last part of the pump code as shown.

“XTS” in place of “TTS”.

This indicates the following specification amendments :-

Certain seals and o-rings can be changed from Buna-N to Viton and back-up diaphragms and any bump-stops will

be changed to Viton.

See table below for parts effected :- (refer to main table for quantities / pump)

These items are available in recommended spares kit :- ASK5005HT

HIGH TEMPERATURE INSTRUCTIONS