Airvantage troubleshooting – Blagdon Pump AVX75 Metallic User Manual

Page 11

Advertising
background image

avx75mdl1sm_haz duty-rev0112

Model AVX75 Hazardous Duty Metallic Page 9

Caution! Whenever troubleshooting or performing any repairs on any

BLAGDON equipment, always remove air supply line to the pump and wear

proper personal protective equipment.

LED OUTPUT FOR AirVantage UNIT

STATE

LED OUTPUT

Startup/Settle/Deadhead

Solid

Standby/Low Flow

1 Second ON / 1 Second OFF

Learn Mode

0.1 Seconds ON / 0.1 Seconds OFF

Seek/Optimize

1 Second ON / 0.1 Seconds OFF

Steady State/Air Savings

OFF / ON in rhythm with Cycle Rate of Pump

AirVantage LED DOES NOT LIGHT UP AT ALL

What to Check:

• Make sure power switch on the control module is turned on, (depressed to the left)

• Make sure air is being supplied to pump or make sure 110 VAC unit has power

being supplied to it

Corrective Action:

• Cycle power switch off/on

• Unplug patch cable and cycle power switch off/on

• Consult Factory After Sales Support team

AirVantage LED LIGHTS UP AND STAYS ON SOLID

What to Check:

• Make sure patch cable is plugged in and locked

Corrective Action:

• Consult Factory After Sales Support team

VALVE FIRES ONCE AND IMMEDIATELY RESETS

Corrective Action:

• Consult Factory After Sales Support team

AirVantage Troubleshooting

VALVE LED NEVER LEAVES SEEK MODE - AirVantage LED PULSING IN TIME TO

PUMP, BUT VALVE NOT ACTUATING AND THE PUMP IS NOT SAVING AIR

Corrective Action:

• Consult Factory After Sales Support team

UNEXPECTED OPERATING CONDITION (AIR SAVINGS OR FLOW RATE)

What to Check:

• Check for varying environmental pumping conditions (changing head or suction)

• Check ice buildup in exhaust area

• Inspect sleeve and spool set for damage

Corrective Action:

• Consult Factory After Sales Support team

PUMP CYCLING IS UNSTABLE OR ERRATIC

What to Check:

• Run pump without AirVantage and check pump operation

• Make sure pump has correct sleeve and spool set installed

• Make sure patch cable plug is connected and locked

• Make sure power wire connectors are tight

Corrective Action:

• Consult Factory After Sales Support team

PUMP RUNNING SLOWLY

What to Check:

• Run pump without AirVantage and check operation

• Cycle the power off/on to the control module to reset controller

• Check ice buildup in exhaust area

• Inspect sleeve and spool set for damage

Corrective Action:

• Consult Factory After Sales Support team

• Cycle the power switch on the control module off/on

Do not open when an

explosive atmosphere

may be present.

WARNING

Advertising