Airvantage troubleshooting continued – Blagdon Pump AVB75 Metallic User Manual

Page 12

Advertising
background image

avbmdl1sm-rev0111

Model AVB Metallic Page 10

AirVantage Troubleshooting Continued

AirVantage RESETS AND ENTERS LEARN MODE TOO FREqUENTLY

What to Check:

• Check for excessive varying environmental pumping conditions

(changing head or suction)

• Check ice buildup in exhaust area

• Inspect sleeve and spool set for damage

• Make sure patch cable plug is connected and locked

Corrective Action:

• Consult Factory After Sales Support Team

PUMP STALLS, RESETS, LEARNS, SEEKS AND REPEATS

What to Check:

• Make sure patch cable plug is connected and locked

• Check ice buildup in exhaust area

Corrective Action:

• Consult Factory After Sales Support Team

PUMP MOVES OUT OF STEADY STATE AND NEVER

ATTEMPTS TO RELEARN (LED ON)

What to Check:

• Make sure patch cable plug is connected and locked

• Cycle the power off/on to the control module

Corrective Action:

• Consult Factory After Sales Support Team

• Cycle the power switch on the control module off/on

WHAT TO DO IN THE EVENT OF A DIAPHRAGM FAILURE

If a diaphragm failure has been detected in pumps fitted with AirVantage,

see page 5 for shut-down procedure.

What to Check:

• Has product migrated to the sensor?

Corrective Action:

• If the sensor has been submerged in product, the sensor will need to be

replaced. Consult the AirVantage servicing section of the manual for detailed instructions.

What to Check:

• Has product contaminated the poppet valve?

Correct Action:

• If a significant amount of product has made it into the poppet valve, then the unit will

need to be disassembled for inspection. Consult the AirVantage servicing section (p.22).

VALVE, POPPET

VALVE, SOLENOID

CAPSCREW, HEX SOC HD, 10-32 X .50

COVER

SEAL, O-RING

SEAL, O-RING

MUFFLER

SEAL, O-RING

ASSEMBLY, POWER GENERATOR

CAPSCREW, HEX SOC HD, 10-32 X 2.25

SEAL, O-RING

CAPSCREW, HEX SOC HD, 10-32 X 1.00

CAPSCREW, HEX SOC HD, 10-32 X .50

O-RING

O-RING

CONTROL MODULE

REGULATOR

Optional 1/4" NPT Pipe Plug (P/N 618.011.330)

Must be installed if performing direct spray

wash-down of pump (Purchased Separately)

Advertising