Darex XT-3000 attachments manual (LEX050) User Manual

Page 17

Advertising
background image

57

Congratulations on the purchase of your Darex
XT-3000
90°-120° Sharpening Attachment. As
part of the assembly you should have a
Sharpening fixture (SA16995XA) and Drill Chuck
(SA16890TA) range 3mm to 12mm. (SA016880TA

12mm to 21mm chuck available as optional
accessory.)


By now you are familiar with the ‘quick disconnect’
feature of your
XT-3000. Start
by replacing the
current fixture
with the 90°-
120°
attachment.

Set your desired
point angle by
pulling the red
Pivot Lock Lever
(counter
clockwise)
towards the
operator

and

sliding the fixture across the base plate to the
desired point angle.
Lock the fixture by returning the red Pivot Lock
Lever to its original position.

Use the XT-3000
alignment to align the drill
in the same manner that
you are accustomed to.
The Alignment tube should
be positioned at the

118°

mark.

With the red Slide Handle
touching the Alignment
casting, tighten the Chuck
by rotating the Chuck Knob
clockwise.

Remove the Chuck.

Gently slide the Chuck into the Sharpening fixture.
While keeping the Swing Cam in contact with the
Swing Cam Bearing, apply slight pressure into the
Grind wheel and rotate the chuck clockwise. Try
to sharpen the drill in such a manner that the drill
is off the wheel before you reposition you hand on
the Chuck Knob. Grinding time will vary depending
on wheel condition and amount of material
removal but it should require a minimum of 8-10
rotations.

90º - 120º Drill Attachment

LEX300

CORRECT INCORRECT

Advertising