Section 6: SMA Protocol

05/11 74

51209 Revision 2

6.3.10 Request for Taring with Fixtare Value


Command
:

<LF>T<xxxxxx.xxx><CR>

Reply:

The scale makes a taring attempt using the fixtare value <xxxxxx.xxx> and signals the
tared status in the <s> and <n> characters.

<LF><s><r><N><m><f><xxxxxx.xxx><uuu><CR>

For details, see Chapter 6.6.1 .


6.3.11 Request for Zero Setting of the Scale


Command
:

<LF>Z<CR>

Reply:

The scale makes a zero setting attempt and signals the zero status in the <s>
character.

For this function, the stability condition must be met. The maximum waiting time for
stability is set under [Tare timeout]; see Chapter 5.4.19.

<LF><Z><r><n><m><f><xxxxxx.xxx><uuu><CR>

For details, see Chapter 6.6.1 .

Unless the scale is in the zero setting range, an error reply is generated.


6.3.12 Request for Tare Resetting


Command
:

<LF>C<CR>

Reply:

The scale deletes the tare weight and signals the tare reset status in the <n> status
character. The scale tare is reset.

<LF><s><r><G><m><f><xxxxxx.xxx><uuu><CR>

For details, see Chapter 6.6.1 .


6.3.13 Scale Diagnosis


Command
:

<LF>D<CR>

Reply:

The scale starts the diagnosis and returns a diagnosis reply.

<LF><r><e><c><m><CR>

For details, see Chapter 6.6.1 .