Fairbanks X SERIES PR 5220 ETHERNET TRANSMITTER User Manual
Page 73

Section 6: SMA Protocol
05/11 74
51209 Revision 2
6.3.10 Request for Taring with Fixtare Value
Command
:
<LF>T<xxxxxx.xxx><CR>
Reply:
The scale makes a taring attempt using the fixtare value <xxxxxx.xxx> and signals the
tared status in the <s> and <n> characters.
<LF><s><r><N><m><f><xxxxxx.xxx><uuu><CR>
For details, see Chapter 6.6.1 .
6.3.11 Request for Zero Setting of the Scale
Command
:
<LF>Z<CR>
Reply:
The scale makes a zero setting attempt and signals the zero status in the <s>
character.
For this function, the stability condition must be met. The maximum waiting time for
stability is set under [Tare timeout]; see Chapter 5.4.19.
<LF><Z><r><n><m><f><xxxxxx.xxx><uuu><CR>
For details, see Chapter 6.6.1 .
Unless the scale is in the zero setting range, an error reply is generated.
6.3.12 Request for Tare Resetting
Command
:
<LF>C<CR>
Reply:
The scale deletes the tare weight and signals the tare reset status in the <n> status
character. The scale tare is reset.
<LF><s><r><G><m><f><xxxxxx.xxx><uuu><CR>
For details, see Chapter 6.6.1 .
6.3.13 Scale Diagnosis
Command
:
<LF>D<CR>
Reply:
The scale starts the diagnosis and returns a diagnosis reply.
<LF><r><e><c><m><CR>