Section 1: General Information

09/07

8

51172 Revision 1

SPECIFICATIONS

Capacities

50, 75, 100, 150, 250, 500, 1,000 and 2,500 lbs.

Mount Construction

• Stainless steel Base Plate
• Reinforced Neoprene Top Plate

Full Scale Output (FSO)

3.0mV/v ± 0.25%

Combined Error (FSO)

≤ 0.03%

Non-Linearity (FSO)

≤ 0.03%

Hysteresis (FSO)

≤ 0.02%

Creep Error (20 min.)

≤ 0.03%

Compensated Temperature

14° to 104° F (-10° C to 40° C)

Operating Temperature

-4° to 140° F (-20° – 60° C)

Excitation Voltage

5-15 VDC

Mechanical Overload

• Safe = 150% • Ultimate = 300%

Side-load

Safe = 100%

Reject Ratio

500:1

Bridge Resistance

350 ohms nominal

Load Cell Construction

• Stainless Steel 17-4 PH (50-250 Capacity)
• Alloy Tool Steel (500-2,500 Capacity)

Cable

20 ft. Polyurethane

Protection

IP 66

Approvals

• Factory Mutual Approved
• NTEP CC #07-009 – Capacities 500 lbs. and greater

Omnicell9101 FB

Bending Beam

design with

capacities equal to or less than 250 pounds

Omnicell9101 FB

Shear Beam

design with

capacities greater than 250 pounds

Advertising