Fasten the reducer case with the 6 M8x50 screws, and calibrate the screws with a torque wrench (fig 21) as
indicated in Paragraph 3. Insert the ring gear on the shaft, insert the washer, and use a torque wrench to
tighten the screw to the value indicated in paragraph 3 (fig. 22).
Apply the Ø5 pins to the reducer case (1, fig. 23). Preassemble the bearing on the pinion and insert it
thoroughly in the seat on the reducer case using a slide hammer (fig. 24).
2.1.5 Reassembly of the reducer unit
Pre-assemble the reducer case using standard tools.
Position the gasket (fig. 19) and assemble the reducer case being careful to alight the hole on the reducer
case with the reference pin present on the crankcase (1, fig. 20).
Ref 300902 Rev.A
07-12