To prevent damage to the seal ring, take special care when inserting the seal ring
on the pinion.
Apply O-rings on the inspection covers (1, fig. 92) and tighten with 2+2 M16 x 14 screws (1, fig. 93).
Calibrate the screws with a torque wrench as indicated in paragraph 3 “Screw Tightening Calibration”.
Insert the key 14 x 9 x 60 on the pinion. Apply plugs and lifting brackets with the use of M16 x 30 screws (1,
fig. 94). Calibrate the screws with a torque wrench as indicated in paragraph 3 “Screw Tightening
Calibration:.
Insert oil in the casing as indicated in the use and maintenance manual point 7.4
Ref 300791 Rev.C