background image

cooking

guidelines

-

deluxe

control

12

GENERAL OPERATION - DELUXE CONTROL OVENS

OPERATION

P

reset

Keys Lock and Unlock

p

reset

Keys A through H can be locked in order to

prevent storing, altering or erasing a program.
To lock the P

reset

Keys, press and hold the “I”

Key until the oven beeps. Release the “I” key. The
green indicator on the “I” key will illuminate. Oven
p

reset

Keys A through H are now locked.

Note: Only the oven p

reset

keys A through H are

affected by this lock-out in order to also allow
the oven to be used with the unprogrammed
Cook, Probe, or Hold modes.

To unlock the P

reset

Keys, press and hold the

c

ancel

Key along with the “I” Key for two seconds

until the “I” key light no longer illuminates. Release
all keys. The oven preset keys are now unlocked.

Fahrenheit or Celsius Selection

With the control in the off mode,
press and hold
the u

p

a

rrow

Key until the

display shows the current selection. Press
the up or down buttons to toggle between
the two options. After each change the
button must be released. The display must
clear before the procedure can be repeated.

Control Panel Lock and Unlock

The control panel can be locked at any time in order to
prevent inadvertent or accidental setting changes.
To lock the control panel, press and hold the
u

p

a

rrow

Key and then press the O

n

/O

ff

Key.

You will hear a brief beep and the panel lock
indicator will illuminate. Release all keys.
The oven’s control panel is now locked.
Note: The control panel is now fully locked with the

exception of the O

n

/O

ff

Key and a

rrow

keys.

You will be unable to turn the oven control off at
this point.

To unlock the control panel, press and hold the d

own

a

rrow

Key and then press the O

n

/O

ff

Key. You

will hear three beeps and the panel lock indicator will
extinguish. Release all keys. The panel is now unlocked
and ready for normal use.

Beeper Volume Selection

With the control in the off mode,
press and hold
the D

own

A

rrow

Key

until the display shows the current control
volume. Press the U

p

or D

own

A

rrow

Key

to cycle through the four options
(0 = Off, 1 = Low, 2 = Mid, 3 = High).

A

B

C

D

E

F

G

H

I

A

B

C

D

E

F

G

H

I

Preset