Troubleshooting Guide (Cont.)
General Problem
Possible Cause
Solution
No Shaping Air At
Applicator
No Bearing Air To
Applicator
1. Remote manifold main air input
off
2. No SHP output from Aerobell
Control Unit
3. Improper tubing connection
4. Defective volume booster on
remote manifold
1. Remote manifold main air input
off
2. Improper tubing connection
3. Defective bearing air filter
1. Turn remote manifold main air input
on.
2. See "No SHP air output" on previous
page.
3. Correct tubing connection.
4. Replace volume booster.
1. Turn remote manifold main air input
on.
2. Correct tubing connection.
3. Repair or replace bearing air filter.
9040 Aerobell Control Module - Operation