RMA-303 Dual Purge/Direct Charge - Maintenance
67
Splash Plate Insertion
(55mm and 65mm Bell Cups)
Turn the splash plate removal tool over and use
the large diameter end to press the splash plate
back in place by hand. It may be necessary on
occasions to use an arbor press to install the
splash plate. Press splash plate to a hard stop
(see Figure 31).
Figure 31: Splash Plate Insertion
A11968-01/02 Bell Cup and
Splash Plate Assembly
Splash Plate Removal
After removing the bell cup from the applicator, put
it on a plastic or wood surface to prevent damage
to the edge of the cup. Using the splash plate
removal tool (A11388-00), insert the small end of
the tool into the end of the splash plate assembly.
Press the splash plate out. It may be necessary
to tap lightly with a hammer.
Figure 32: Splash Plate Removal