INSTALLATION
>
The LEPS5001 Power Supply MUST
be located outside the hazardous area (see
NFPA Bulletin No. 33). The user should
be aware of and adhere to all local building
codes and ordinances.
>
This manual MUST be read and thor-
oughly understood by ALL personnel who
operate, clean, or maintain this equipment.
Special care should be taken to ensure that
the WARNINGS and requirements for oper-
ating and servicing safely are followed.
W A R N I N G
!
Install the LEPS5001 Power Supply in a con-
venient area outside the hazardous location,
where it will be protected from the possibility of
any contact with water, vapor or high humidity,
and ambient temperatures in excess of 120
o
F.
The area should be clean, dry, and well ventilated.
>
Do not locate the LEPS5001 Power
Supply near or adjacent to heat producing
equipment such as ovens, high wattage
lamps, steam pipes, etc.
C A U T I O N
!
SAFETY GROUND
Crimp the appropriate connector onto the
Ground Wire Assembly (Part No. 70539, sup-
plied) and install from the Power Supply ground
stud G1 (see Figure 5) to a true earth ground.
LOCATION
>
The Ground Wire Assembly MUST be
connected from the Power Supply ground
stud to a true earth ground.
C A U T I O N
!
17264 CONTROL PANEL
CONNECTIONS
1
17
31
34
Field Ground
From
20593
Power
Supply
1
29
26
25
1
AC Common
AC Control (HOT)
Current Feedback
kV Feedback
Cable Ground Shield
Description
To
LECU5003
Terminal
Figure 2: 17264 Control Panel Connections
Figure 1: LECU5003 Control Panel Connections
White
Black
Black
Red
Grn/Yel
LECU5003 CONTROL PANEL
CONNECTIONS
AC Neutral (4)
AC Hot (5)
I (6)
kV (7)
Field Ground
From
LEPS5001
(TB2)
Wire #
1
17
31
34
Shield
Color
1
17
31
34
G1
To
LECU5003
Terminal #
LEPS5001 Power Supply - Installation
8
Ransburg
CP-95-02.5