INSTALLATION

>

The LEPS5001 Power Supply MUST

be located outside the hazardous area (see

NFPA Bulletin No. 33). The user should

be aware of and adhere to all local building

codes and ordinances.

>

This manual MUST be read and thor-

oughly understood by ALL personnel who

operate, clean, or maintain this equipment.

Special care should be taken to ensure that

the WARNINGS and requirements for oper-

ating and servicing safely are followed.

W A R N I N G

!

Install the LEPS5001 Power Supply in a con-

venient area outside the hazardous location,

where it will be protected from the possibility of

any contact with water, vapor or high humidity,

and ambient temperatures in excess of 120

o

F.

The area should be clean, dry, and well ventilated.

>

Do not locate the LEPS5001 Power

Supply near or adjacent to heat producing

equipment such as ovens, high wattage

lamps, steam pipes, etc.

C A U T I O N

!

SAFETY GROUND

Crimp the appropriate connector onto the

Ground Wire Assembly (Part No. 70539, sup-

plied) and install from the Power Supply ground

stud G1 (see Figure 5) to a true earth ground.

LOCATION

>

The Ground Wire Assembly MUST be

connected from the Power Supply ground

stud to a true earth ground.

C A U T I O N

!

17264 CONTROL PANEL

CONNECTIONS

1

17
31
34

Field Ground

From

20593

Power

Supply

1

29
26
25

1

AC Common
AC Control (HOT)
Current Feedback
kV Feedback
Cable Ground Shield

Description

To

LECU5003

Terminal

Figure 2: 17264 Control Panel Connections

Figure 1: LECU5003 Control Panel Connections

White

Black
Black

Red

Grn/Yel

LECU5003 CONTROL PANEL

CONNECTIONS

AC Neutral (4)

AC Hot (5)

I (6)

kV (7)

Field Ground

From

LEPS5001

(TB2)

Wire #

1

17
31
34

Shield

Color

1

17
31
34

G1

To

LECU5003

Terminal #

LEPS5001 Power Supply - Installation

8

Ransburg

CP-95-02.5