Inputs outputs, Other considerations – Ransburg GMS Ground Monitoring System A12520-XXXX User Manual
Page 12
LN-9265-09.2
12
INPUTS
OUTPUTS
•
110 or 220VAC Main power input
•
The control unit requires an input signal for part detection. A limit switch, photo-eye, PLC or robot signal input is
acceptable.
•
The device will require field calibration to the specific application.
•
The control unit will provide a visual signal to alert the end user of the detection of an ungrounded part.
•
Two contact closures (UNGROUNDED & HV ON) are provided to signal the application of HV and the detection of
an ungrounded part.
•
These contacts may be hooked to a PLC, horn, or light (shown in the PLC INTERFACE section of this manual).
OTHER CONSIDERATIONS
•
Designed for use on non-metallic substrates only.
•
Accuracy of the system is dependent on part to probe detector distance staying consistent.
•
The probe to part distance should be set to 4 inches and should not vary more than ± one (1) inch.
•
Probe detector must stay clean.
•
Inspect the probe detector electrode every two weeks.