Ransburg, Grounding of the color changer, Mcv 2 dual purge color changer - installation – Ransburg MCV2 Dual Purge Color Changer A10986-XX_A10993-XX User Manual
Page 15
Advertising
Figure 5: Grounding the Color Changer
Grounding of the Color Changer
For safety, the color changer MUST be grounded.
Using a 12-gauge wire, ground the output plate
metal mounting screw of the color changer to a
true earth ground. Using an ohm meter, check
for ground, testing the earth ground to the purge
assembly top plate. The resistance should be 10
ohms or less (see Figure 5).
> The color changer MUST be properly
grounded. Proper grounding (as described
below) will prevent static charge buildup and
possible discharge from the color changer.
W A R N I N G
!
NOTE
> Use metal screws for mounting for
grounding purposes.
END PLATE BOLT
OHMS
EARTH GROUND
(TRUE)
10
0
MCV 2 Dual Purge Color Changer - Installation
12
CS-05-01.9
Ransburg