Ransburg, Troubleshooting guide, Color valve stack - maintenance – Ransburg Color Valve Stack CCV-5100 User Manual
Page 17

TROUBLESHOOTING GUIDE
Fluid
Air (to CCV)
Air
Fluid
Air
Fluid
1. No main supply air
2.
No paint connected to CCV
3. Paint not pressurized
1. No main supply air
2. Loose connection
1. Hole in tubing
2. Loose connections
1. Loose connection
2. Worn fluid tubing
1. Insufficient supply air
1. Low supply pressure
2. Clogged or obstructed fluid lines
3. Clogged or obstructed CCV stack
1. Turn supply air on.
2. Reconnect paint.
3. Check users supply.
1. Turn supply air On.
2. Tighten connections.
1. Replace worn tubing.
2. Tighten connections.
1. Tighten connections.
2. Replace worn fluid tubing.
1. Check air regulator.
1. Increase supply pressure.
2. Clean or replace.
3. Clean as required.
General Problem
Possible Cause
Solution
DELIVERY
LEAKAGE
DEFICIENT DELIVERY
14
Color Valve Stack - Maintenance
LN-9113-06.3
Ransburg