Archive, Input connections, External – Ransburg 9040 Classic HV Power Supply 76447 User Manual
Page 16

CP-97-02.5
9040 Classic for REA & M90 Systems - Installation
1 3
1 3
1 3
1 3
1 3
INPUT CONNECTIONS
INPUT CONNECTIONS
INPUT CONNECTIONS
INPUT CONNECTIONS
INPUT CONNECTIONS
Plug the AC line cord into a properly grounded
AC outlet.
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
EXTERNAL
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
High V
High V
High V
High V
High Voltage (High V
oltage (High V
oltage (High V
oltage (High V
oltage (High Voltage)
oltage)
oltage)
oltage)
oltage)
Cable Connection
Cable Connection
Cable Connection
Cable Connection
Cable Connection
Remove the plastic protective plug from the High
Voltage Cable Connector and squirt enough
dielectric oil (70863-00 (supplied)) into the high
voltage tube to cover the electrical contact point.
With a clean, dry cloth, wipe the end of the high
voltage cable. Insert the high voltage cable into
the high voltage cable connector and tighten the
cable nut securely.
Safety Ground
Safety Ground
Safety Ground
Safety Ground
Safety Ground
Crimp the appropriate connector onto the ground
wire assembly and install from the power supply
ground stud, located on the side panel, to a true
earth ground.
Interlocks
Interlocks
Interlocks
Interlocks
Interlocks
As outlined in NFPA-33 and OSHA, the AC power
line must be series interlocked with both the
exhaust fan and conveyor. To interlock the 9040
Classic Power Supply with the exhaust fan and
conveyor, perform the following:
1. Ensure the front panel fuse is removed, the
power supply is unplugged, and the ON/OFF
switch is in the OFF position.
2. Open the power supply cabinet door.
> In general, conduit must be used for ap-
proved AC installation, however, if national
and local codes permit, the AC power may
be supplied via the factory installed line
cord. If conduit is utilized, the power supply
wiring MAY be routed through an optional
explosion proof switch mounted on or near
the spray booth where it will be convenient
to the operator.
N O T E
N O T E
N O T E
N O T E
N O T E
>
When connecting external wires to the
9040 Classic Power Supply, route the wir-
ing through the external wiring grommet
located on the side panel.
N O T E
N O T E
N O T E
N O T E
N O T E
>
Squirting 70863-00 dielectric oil down
the high voltage tube significantly reduces
corona discharge that can cause deterio-
ration of the high voltage connection com-
ponents.
N O T E
N O T E
N O T E
N O T E
N O T E
>
The Ground Wire Assembly MUST
MUST
MUST
MUST
MUST be
connected from the Power Supply Ground
Stud to a true earth ground.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
>
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS ensure that high voltage is
OFF
OFF
OFF
OFF
OFF before flushing the spray gun with
solvent. NEVER
NEVER
NEVER
NEVER
NEVER flush the spray applicator
with high voltage ON
ON
ON
ON
ON, as this is a severe fire
hazard and risk to personnel safety. It is
recommended that the high voltage control
be interlocked with the solvent flush signal
so that high voltage is automatically locked
out whenever flushing occurs. Consult your
authorized ITW Ransburg representative for
information on interlocking the high voltage
OFF
OFF
OFF
OFF
OFF signal with the solvent flush signal.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS double check that the power
supply is unplugged from its AC outlet
before working with any internal wiring.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
ARCHIVE