LN-9217-00.2

AdaptaFlow Node Adapter - Operation

Normal Data BTR Word

Normal Data BTR Word

Normal Data BTR Word

Normal Data BTR Word

Normal Data BTR Word
Configuration

Configuration

Configuration

Configuration

Configuration

Word #

Word #

Word #

Word #

Word # Description

Description

Description

Description

Description

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18

Configuration Word (0)
Channel No. (1-4)
Color No. (1-32)
Actual Flow Channel No. 1 (0-999 cc/min.)
Peak Flow Channel No. 1 (0-999 cc/min.)
Total Flow Channel No. 1 (0-32768 cc)
Analog Out Channel No. 1 (0-4095)
Actual Flow Channel No. 2 (0-999 cc/min.)
Peak Flow Channel No. 2 (0-999 cc/min.)
Total Flow Channel No. 2 (0-32768 cc)
Analog Out Channel No. 2 (0-4095)
Actual Flow Channel No. 3 (0-999 cc/min.)
Peak Flow Channel No. 3 (0-999 cc/min.)
Total Flow Channel No. 3 (0-32768 cc)
Analog Out Channel No. 3 (0-4095)
Actual Flow Channel No. 4 (0-999 cc/min.)
Peak Flow Channel No. 4 (0-999 cc/min.)
Total Flow Channel No. 4 (0-32768 cc)
Analog Out Channel No. 4 (0-4095)

Figure 13: Normal Data BTR Word Configuration

Figure 13: Normal Data BTR Word Configuration

Figure 13: Normal Data BTR Word Configuration

Figure 13: Normal Data BTR Word Configuration

Figure 13: Normal Data BTR Word Configuration

1 9

1 9

1 9

1 9

1 9

Global Data Block T

Global Data Block T

Global Data Block T

Global Data Block T

Global Data Block Transfer

ransfer

ransfer

ransfer

ransfer

Read Operational Descriptions

Read Operational Descriptions

Read Operational Descriptions

Read Operational Descriptions

Read Operational Descriptions

-Refer to Figure 14

-Refer to Figure 14

-Refer to Figure 14

-Refer to Figure 14

-Refer to Figure 14

The Global Block Transfer Read is identified by a
configuration word of two. This file is returned
immediately following a Global BTW instruction or
this data may also be requested by setting the
Normal BTW instructions configuration word to a
two.

Configuration Word

Configuration Word

Configuration Word

Configuration Word

Configuration Word

The configuration Word will equal a 2 to designate
that this BTR file represents Global Data.

The balance of the BTR words in this file are
described under the Global BTW section.

Actual Flow

Actual Flow

Actual Flow

Actual Flow

Actual Flow

This value is the real time flow rate for each
channel.

Peak Flow

Peak Flow

Peak Flow

Peak Flow

Peak Flow

This is current peak flow for each channel.

Total Flow

Total Flow

Total Flow

Total Flow

Total Flow

Value for total accumulated fluid delivered between
totalizer reset signals. This value can be zeroed
by a software command or by a hardware reset.
This can be used as a subtotal or intermediate total
to account for fluid delivered per job or shift, etc.

Analog Out

Analog Out

Analog Out

Analog Out

Analog Out

This is the current analog output value.