Chapter 4 function test & alignment procedure, Function test & alignment procedure, 1 test equipment needed – Acer P1166 User Manual

Page 67: 2 service mode, 3 osd reset

Advertising
background image

P1166 / P1266 / P1266i / P1166P / P1266P Confidential

4-1

Chapter 4

Function Test & Alignment Procedure

4-1 Test Equipment Needed

- IBM PC with XGA resolution and Wireless Network Card
- DVD player with Multi-system (NTSC/PAL/SECAM), equipped “Component”, “S-Video” ,
“Composite” and "HDMI".
- HDTV Source (480P, 720P, 1080P)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- After changing parts, check the information below.

4-2 Service Mode

1. Turn on the projector and input the signal
2. Do the following actions sequentially to get into service mode
(1) Press "Power→Left→Left→Menu".
(2) Service mode will be shown.
(3) After confirming the configuration, press "Exit" to exit.

4-3 OSD Reset

1. After final QC step, we have to erase all saved change again and restore the OSD

default setting. The following actions will allow you to erase all end-users' settings and

restore the default setting:

(1) Please get into OSD menu.
(2) To execute "Reset" function.