This procedure checks the coolant system for leaks.
A drop in pressure indicates a leak in the system
that must be repaired before refilling the system
with coolant.

IMPORTANT: For correct operation of the
75700 unit, adjust Valve 1 and Valve 2 in the
sequence specified in these instructions.

1. Turn the regulator on the 75700 control panel

counterclockwise (CCW) to lower the test
pressure. See Figure 10.

Note: Adjusting the regulator requires pulling up
on the regulator knob, and then turning the knob.

2. Turn Valve 1 to PRESSURE TEST.

3. Turn Valve 2 to PRESSURIZE.

4. Adjust the regulator clockwise to the correct test

pressure.

l

l

l

l

l

Figure 10

l

l

l

l

l

Valve 1

Valve 2

CAUTION: To prevent damage to the

vehicle, test pressure must range BELOW the
pressure indicated on the radiator cap,
overflow cap, or vehicle specifications.

Pressure Gauge

Regulator

5. Turn Valve 2 to HOLD.

6. Observe the pressure gauge on the control panel:

• a constant pressure reading indicates no leaks

in the system;

• a drop in pressure indicates a leak in the system

that must be repaired.

Note: The cooling system may need to be
pressurized more than once to equalize test
pressure throughout the system.

7. If a leak must be repaired, turn both valves to

VACUUM to relieve pressure. Perform repairs,
and repeat the Pressure Test.

If no repairs are needed, proceed to the Exchange
Procedure.