Adding refrigerant to the tank, Spx robinair – Robinair AC900 Station User Manual

Page 2

Advertising
background image

Adding Refrigerant to the Tank

Follow diagram for connections to source tank. Close
LIQUID valve on tank before disconnecting blue LIQUID
hose.

For R-12 source tanks, connect 6” yellow adapter to
tank fitting before connecting hose.

Open valve on source tank.

Open GAS (vapor) valve on unit’s tank.

Press ADD.

Display shows amount transferred to tank.

Transfer stops automatically when source tank is
empty or when weight in station tank reaches 15
pounds. Display shows “CPL.”

Close source tank valve and disconnect blue
hose (or 6” yellow adapter fitting, if used) from
source tank. Reconnect blue hose to LIQUID
valve of tank.

121267 (2/99)

Printed In USA

SPX ROBINAIR

SPX Corporation

1224 Robinair Way

Montpelier, OH 43543 USA

Phone 419-485-5561

Fax 419-485-8300

Blue Liquid Hose

Source
Tank

Advertising
This manual is related to the following products: