Specifications 21 – AT&T Partner Plus User Manual

Page 25

Advertising
background image

SMDR Output

1200 baud

Format

No parity

8 data bits

2 stop bits

Environmental

Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)

Requirements—

Locate within 5 feet (1.5 meters) of the network interface jacks and an electrical outlet not

Control Unit

controlled by a switch, using supplied 7-foot (2.1-meter) cords

Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight

Humidity 15%–90%, noncondensing

For proper ventilation and easy replacement of modules, provide at least 6" (2.34cm) clearance
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.

Locate in an area free of excess moisture, corrosive gases, dust, and chemicals

Electrical

90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps

Requirements

On a PARTNER Plus 220V System: 180–264 VAC, fused at 10 Amps

Outlet must not be controlled by an on/off switch

Grounding to comply with Underwriters Laboratories (UL) 1459:

A. An insulated grounding conductor that is not smaller in size and equivalent in insulation

material and thickness to the grounded and ungrounded branch circuit supply conductors,
except that it is green with or without one or more yellow stripes, is to be installed as part of the
circuit that supplies the product or system.

B. The grounding conductor mentioned in item A is to be connected to ground at the service

equipment.

C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a

grounding type, and the grounding conductors serving these receptacles are to be connected
to earth ground at the service equipment.

Requirements for

Installation of a telephone or other standard (tip/ring) device in another building requires the

Out-of-Building

following In-Range Out-of-Building (IROB) protectors to protect the control unit and device from

Extensions

electrical surges:

MLS-model telephone: two AT&T IROB protectors

Standard device: one AT&T IROB protector plus one carbon block protector

Wiring

MLS-model phones: AT&T SYSTIMAX™ or at least 2-pair (4-wire) star (“home run” not “loop”)

Other standard telecommunications equipment (single-line phones, fax machines, answering

machines, etc.): 1-pair (2-wire) mounting cords (AT&T D2R mounting cords recommended)

Bridging adapter: AT&T 267F2

Range: 1,000 feet (305 meters) for MLS phones; 3,000 feet (915 meters) for standard devices

Safety

U.S.: Meets UL 1459 Issue 2

Requirements

Canada: Meets CSA C22.2, 225

Government

U.S.:

FCC Part 68

Approvals and

FCC registration number (U.S.): AS5 USA-61630-KF-E

Local Phone

FCC Part 15 Class A

Company

REN (outside line jack): 0.9A per line jack

Information

Jack type: RJ11C

Canada: DOC CP01, Issue 7

DOC registration number (Canada): 230 3756
DOC CS03, Issues 6 & 7
Load Number = 7
Loop start lines

Specifications

21