Self purge/ auto evacuate – Robinair 25175B REFRIGERANT RECOVERY SYSTEM User Manual

Page 12

Advertising
background image

SELF PURGING YOUR 25175B

PROCEDURE FOR PURGING REMAINING REFRIGERANT FROM THE 25175B

1. Close the ports of the system being serviced that

are connected to the input port of the 25175B.

2. Close the input port on the 25175B.

3. Turn off the 25175B.

4. Turn the Recover/Purge valve to the Purge posi-

tion.

5. Restart the 25175B.

6. Run until desired vacuum is achieved.

7. Close the ports on the recovery tank and the

25175B.

8. Turn the 25175B off.

9. Return the Recover/Purge valve to the Recover

position.

10.Disconnect and store all hoses.

11.Replace the in-line filter on your 25175B after

every job.

SELF PURGE/ AUTO EVACUATE

To change from Recovery mode to Purge follow the steps below:

1. Close the Input port

2. Turn the unit off (to prevent high pressure shutoff).

3. Switch to Purge position.

4. Restart the unit.

11

Advertising