Recover/Recycle/Recharge Unit

23

Periodically, the internal storage vessel (ISV) will require additional refrigerant.
Use the following steps to add refrigerant to the ISV.

1. Connect the R-134a tank adapter to the liquid valve on the refrigerant

source tank.

2. Connect the service coupler of the low-side hose (blue) to the adapter.

NOTE: If using a refillable source tank, connect to the vapor valve.

3. Open the valve on the source tank, place the tank upside down in the

source tank compartment, and secure the source tank strap around the
tank.

4. Press the Mode key until RECOVER XX.XXLBS (KG) is displayed. (XX.XX

is the amount of refrigerant capacity remaining in the ISV.)

5. Press the Arrow keys to adjust to the desired recover weight.

Note: Although the display shows the refrigerant capacity remaining in the
ISV,

the ISV should not be filled to this level

. At least 9 lbs. (4 kg) of

refrigerant capacity should be available in the ISV after filling to allow
space for the next A/C recovery. Therefore, adjust the unit to fill the ISV to
a level at least 9 lbs. (4 kg)

less

than what the display shows as the

remaining refrigerant capacity.

6. On the control panel, open the low-side valve; verify the high-side valve is

closed.

7. Press the Start/Stop key. The ISV begins filling, and the screen displays

the amount of refrigerant being transferred to the ISV.

8. The unit will automatically stop when the desired amount has been

transferred to the ISV. The display will flash between:

and

NOTE: Drain oil after the internal storage vessel is filled.

9. Unstrap the source tank, remove it from its compartment, then close the

source tank valve.

10. Disconnect the hose from the tank.

11. Cap the source tank with its original tank cap. For storage, place the source

tank upright in the source tank compartment, and secure the source tank
strap around the tank.

Adding Additional Refrigerant to the Internal Storage Vessel

RECOVER

XX.XXLBS

DRAIN OIL

Maintenance

R-134a Tank

Adapter

Advertising